Honeywell’s 5808W3 is a 3V lithium powered, photoelectronic smoke/heat detector with a built-in wireless transmitter. It is intended for use with any 5800 Series Wireless Receiver/Transceiver for residential installations (for commercial installations, the 5881ENHC or the 5883H receiver is required).
The transmitter can send alarm, tamper, maintenance and battery condition messages to the system’s receiver. Smoothing algorithms minimize nuisance alarms by smoothing out short term spikes from dust and smoke – virtually eliminating nuisance alarms.
Since there are no holes to drill or wires to run, you can preserve the beauty of the building while protecting it. The 5808W3 is an ideal smoke detector for those difficult to wire locations, applications where room aesthetics are critical, or where hazardous materials exist.
All models also feature a restorable, built-in, fixed temperature (135°F) thermal detector that is also capable of sensing a pre-freeze condition if the temperature is below 41°F.
Features
- Improved Robust RF Field Strength
The distance between the detector and receiver has been significantly increased without the need for a repeater
- Smoothing Algorithms
Mathematical calculations in the detector’s software that minimize nuisance alarms by smoothing out short term spikes from dust and smoke
- Smart Check
A signal is sent to the control panel when the detector requires cleaning. This allows a regular, non-emergency service call to clean the detector before it goes into alarm.
- Drift Compensation
Virtually eliminates nuisance alarms from long-term dust build-up by automatically adjusting the detector’s sensitivity
- Removable Detector Cover and Chamber Top
The technician is able to quickly and easily clean the detector chamber without disassembling the detector head
- Approved UL Listings for Residential and Commercial Applications
Both residential and commercial installation requirements are met
- Additional LED Status Indicators
Identifying between alarm or trouble conditions is a snap with green and red LED status indicators. A green LED denotes a normal condition while the red LED indicates abnormal conditions
- Easy-to-install Mounting Base
The sturdy mounting base allows the detector to be more easily installed on uneven surfaces (i.e. stucco). The mounting base has larger mounting ports, which accommodate drywall anchors for easy surface mounting.
ADDITIONAL FEATURES
- Utilizes one long-life 3V lithium battery
- Microcontroller runs on a 4.0 MHz clock
- Horn operates at 3.3 KHz with sound pressure level of 85 dBA at 10 feet
- Built-in wireless transmitter, temporal code 3 sounder
- Maintenance signal fully complies with the sensitivity test requirement specified in NFPA 72, 7-2.2 and is approved by UL
The powerful 5808LST is a combination wireless photoelectric smoke and heat detector that trips when temperatures reach 135º F. Ideal for difficult to wire locations, situations where room aesthetics are critical or where hazardous materials exist, the 5808LST provides the ultimate in installation flexibility.
Remarkably cost-effective, the attractive, low profile unit blends easily with any décor and provides benefits rarely found in smoke detectors in this price range. Smart Check™ remote maintenance reporting automatically alerts the central station when it is in need of service, and built-in drift compensation continuously corrects sensitivity variances caused by dust. The 5808LST is UL 268 listed for use in both commercial and residential applications.
Features
- Low profile housing
- Extended battery life – Two 3V Lithium
- Automatic drift compensation
- Smart Check™ – pre-alarm maintenance signal
- Test/alarm silence button – Immediate signal 2.5 sec delay horn activation
- Field replaceable chamber
- Heat Detector – dual 135° thermistors
- Low temperature alert signal
- Temporal Code 3 sounder
- Pre-Low battery signal to central station (if applicable) seven days prior to horn chirp
- UL 268 – Commercial and Residential
Honeywell’s 5809 wireless fixed heat and rate-of-rise temperature sensor offers expanded fire detection and installation flexibility. It is ideal for hard to wire locations and applications that require more than smoke detection. With no wires to run, the 5809 is fast and easy to install.
The 5809 combines both rate-of-rise and fixed temperature sensors. Fires typically cause a rapid rise in temperature in the surrounding area. The 5809’s rate-of-rise thermostat senses the rise in temperature and signals an alarm if the increase is 15° or more per minute. A built-in fixed temperature sensor will also signal an alarm if the environmental temperature rises above 135°F. The 5809 is UL Listed (UL521) and CSFM approved for commercial and residential applications.
Features
- Contains a built-in transmitter which can send alarm, supervisory and battery condition messages to the system’s receiver/control unit
- Powered by a three-volt lithium battery. If the battery voltage gets too low, the 5809 sends a low battery signal to the control panel
- Features a tamper switch, which causes a trouble signal to be sent to the control if the unit is removed from the mounting base
- UL Listed for Commercial (when using 5881EH Receiver) or Residential applications
Honeywell’s 5806W3 is a 3V battery operated, photoelectronic smoke detector with a built-in wireless transmitter. It facilitates fire verification for false alarm reduction requirements by ANSI/SIA CP-01standards and is intended for use with any of Honeywell’s 5800 Series wireless receiver/transceivers for residential installations. The 5881ENHC or 5883H receivers are required for commercial installations. The transmitter can send alarm, tamper, maintenance and battery condition messages to the system’s receiver. The maintenance signal fully complies with the sensitivity test requirement specified in NFPA 72, 7-2.2 and is UL approved. The 5806W3 incorporates a state-of-the-art optical sensing chamber and advanced microprocessor. The microprocessor allows the detector to automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminants settling into the unit’s smoke chamber. Since there are no holes to drill or wires to run, installers can preserve the beauty of the protected premise while protecting it. The 5806W3 is an ideal smoke detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist.
Features
- Smoothing Algorithms
Mathematical calculations in the detector’s software that minimize nuisance alarms by smoothing out short term spikes from dust and smoke.
- Smart Check
A signal is sent to the control panel when the detector requires cleaning. This allows a regular, non-emergency service call to clean the detector before it goes into alarm.
- Drift Compensation
Virtually eliminates nuisance alarms from long-term dust build-up by automatically adjusting the detector’s sensitivity.
- Removable Detector Cover and Chamber Top
Provides the technician the ability to quickly and easily clean the detector chamber without disassembling the detector head.
- Approved UL Listings for Residential and Commercial Applications
Both residential and commercial installation requirements are met.
- Additional LED Status Indicators
Identifying between alarm or trouble conditions is easier with green and red LED status indicators. The green LED denotes a normal condition while the red LED indicates an abnormal condition.
- Easy-to-install Mounting Base
The sturdy mounting base allows the detector to be more easily installed on uneven surfaces (i.e. stucco). The mounting base has larger mounting ports to accommodate drywall anchors for easy surface mounting.
- Improved Robust RF Field Strength
The distance between the detector and receiver has been significantly increased.
Additional Features:
- Utilizes one long-life 3V lithium battery
- Microcontroller runs on an 4.0 MHz clock
- Horn operates at 3.3 KHz with sound pressure level of 85dBA at 10 feet
- Built-in wireless transmitter, temporal code 3 sounder